Limit load based evaluation of plastic η factor for C(T) specimen with a mismatched weld

Authors

  • R Nikhil Materials development and Technology Division, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102, Tamil Nadu, India
  • S A Krishnan Indira Gandhi Centre for Atomic Research
  • G Sasikala Indira Gandhi Centre for Atomic Research
  • A Moitra Indira Gandhi Centre for Atomic Research

DOI:

https://doi.org/10.3221/IGF-ESIS.48.50

Keywords:

Limit Load, Eta, strength mismatch

Abstract

Plastic η factor is adopted to account crack tip plasticity while evaluating the fracture toughness of the materials as per ASTM E1820. It is valid only for homogeneous materials. The plastic η factor for compact tension geometry (CT) with type 316LN stainless steel weld has been evaluated based on elastic-plastic FE analysis. The incremental elastic-plastic material model with various values for strength mismatch level (M), from 1.2 to 2.2 has been considered for the weld. The weld width (h) parallel to the crack plane is varied from 4 mm to 16 mm. The η values thus obtained are analyzed and the inferences are discussed.

Downloads

Download data is not yet available.

Published

05-03-2019

How to Cite

Limit load based evaluation of plastic η factor for C(T) specimen with a mismatched weld. (2019). Frattura Ed Integrità Strutturale, 13(48), 523-529. https://doi.org/10.3221/IGF-ESIS.48.50