High-quality nodule analysis in spheroidal graphite cast iron using X-ray micro-computed tomography

Authors

  • Juan Toledo Departamento de Ingeniería Industrial, Universidad Tecnológica Nacional-Facultad Regional Rafaela, Acuña 49, Rafaela, Santa Fe, Argentina. https://orcid.org/0000-0002-6047-035X
  • Felipe Diaz Departamento de Ingeniería Electromecánica, Universidad Tecnológica Nacional-Facultad Regional Rafaela-CONICET, Acuña 49, Rafaela, Santa Fe, Argentina https://orcid.org/0000-0003-4998-5536
  • Matías Peralta Departamento de Validación de Equipos y Componentes, Instituto Nacional de Tecnología Industrial-Centro Litoral, Ruta Nacional N°34 km 227.6, Rafaela, Santa Fe, Argentina https://orcid.org/0000-0001-5807-8618
  • Diego Fernandino INTEMA, Universidad Nacional de Mar del Plata-CONICET, Av. Colón 10850, Mar del Plata, B7606BVZ, Argentina https://orcid.org/0000-0003-4647-2663

DOI:

https://doi.org/10.3221/IGF-ESIS.62.20

Keywords:

X-ray micro-tomography, Sphericity, Compactness, Nondestructive analysis, Spheroidal graphite cast iron

Abstract

This work is a continuation of the studies presented in a recent paper by the authors, where a methodology to obtain different nodule quality categories in spheroidal graphite cast iron, was proposed. In this study, an exhaustive analysis of the highest-quality graphite nodules was performed. The experimental methodology involves X-ray micro-computed tomography analysis and digital image post-processing of the high-quality graphite nodule population. Furthermore, different subpopulations were selected, following a nodular size criterion. The procedure involves the evaluation and comparison of the sphericity and compactness distributions and the distances between neighbouring nodules by using ad-hoc image processing software. The results reveal the complementary nature of the sphericity and compactness parameters, which allow classifying, with great accuracy, different nodular quality categories of spheroidal graphite cast iron. Additionally, new viewpoints about the nodular morphology study and the distribution of quality nodules in the metallic matrix was provided, which could be extended to other heterogeneous materials.

Downloads

Download data is not yet available.

Published

22-09-2022

How to Cite

High-quality nodule analysis in spheroidal graphite cast iron using X-ray micro-computed tomography. (2022). Frattura Ed Integrità Strutturale, 16(62), 279-288. https://doi.org/10.3221/IGF-ESIS.62.20